Devens Sustainable Housing Demonstration Project

  • End Type: No
  • Regional Office: Boston
  • Submitted: No
  • Approved: No
  • Modified: 2010-03-25
  • Stage: Planning
  • Visit: No

Specification 4726

  • Percent Energy Savings: 7
  • Submitted: No
  • Approved: No
  • Floor Plan: Unknown

Specification 4854

  • Percent Energy Savings: 0
  • Submitted: No
  • Approved: No
  • Editor: Srikanth Puttagunta
  • Modified: 2011-04-27 10:36:00
  • Floor Plan: Townhome
  • Style: Single-family attached, site built
  • Number of Stories: 2.0
  • Number of Bedrooms: 2
  • Floor Area: 1320.0
  • Roof Framing: Unvented attic - truss framing
  • Roof Insulation: Sprayed cellulose
  • Roof R Value: 59.0
  • Wall Framing: Wood - 2x4 - 24 in o.c.
  • Wall Insulation: Sprayed cellulose
  • Wall R Value: 48.0
  • Wall Sheathing: Other
  • Wall Sheathing Other: Double wall framing, ccSPF
  • Foundation Type: Conditioned basement
  • Foundation Construction: Block
  • Foundation Insulation: Rigid foam
  • Foundation R Value: 13.0
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.26
  • Window SHGC: 0.3
  • Space Heating Type: Gas furnace
  • Space Heating Combustion: Power vented
  • Space Heating Efficiency: 94.0
  • Space Heating Location: Basement
  • Space Heating Energy Proto: 48.0
  • Space Heating Energy: 100.0
  • Space Heating Fuel: Gas
  • Light Eff Type: 2
  • MEL Load: 1
  • Cooling Type: Electric Air Conditioner (split system)
  • Cooling Capacity: 1.5
  • Cooling SEER: 16.0
  • Cooling Fuel: Electric
  • Duct Type: Combination
  • Duct Location: In conditioned space
  • Air Distribution Location: Basement
  • Vent Type: Controlled exhaust
  • Vent Control: Other (or combination of the above)
  • Hot Water Type: Gas - tankless
  • Hot Water Backup: Other
  • Hot Water Combustion: Power vented
  • Hot Water Location: Basement
  • Hot Water Efficiency: 0.88
  • Hot Water Fuel: Natural Gas
  • Benchmark Version: 2008
  • Total Energy Use: 100.0
  • Total Energy Use Proto: 48.0
  • Percent Energy Savings: 52.0
  • Total Energy Savings: 52.0
  • Site Gen: None

Data and Resources

Additional Info

Field Value
Author Srikanth Puttagunta
Maintainer Srikanth Puttagunta
Last Updated September 16, 2016, 22:27 (Etc/UTC)
Created September 16, 2016, 22:27 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Cold
City Devens
State MA
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 1970-01-01
Project Actual End Date 1970-01-01
Completed House Count 1
Expected House Count 1
Energy Savings Percentage 3
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1

Dataset extent

Map data © OpenStreetMap contributors