36-38 Harriet St

  • End Type: No
  • Regional Office: Seattle
  • Submitted: No
  • Approved: No
  • Modified: 2010-03-26
  • Stage: Design
  • Visit: No

Specification 4729

  • Percent Energy Savings: 7
  • Submitted: No
  • Approved: No
  • Floor Plan: Unknown

Specification 4730

  • Percent Energy Savings: 59
  • Submitted: No
  • Approved: No
  • Editor: David Springer
  • Modified: 2010-04-15 00:00:00
  • Model Name: Multi family building
  • Floor Plan: 300 s.f. Nanoloft
  • Style: Manufactured housing, modular
  • House Type: Production (G3)
  • Number of Stories: 1.0
  • Number of Bedrooms: 1
  • Floor Area: 300.0
  • Basement Area: 0.0
  • Conditioned Volume: 2700.0
  • Roof Framing: Flat
  • Roof Insulation: Spray Foam
  • Roof R Value: 40.0
  • Roof Radiant: No
  • Roof Upgrades: R-6 at deck
  • Wall Framing: Wood - 2x6 - 24 in o.c. (Advanced Framing)
  • Wall Insulation: Spray Foam
  • Wall R Value: 19.0
  • Wall Sheathing: XPS
  • Wall Sheathing R Value: 5.0
  • Wall Radiant: No
  • Foundation Type: Other
  • Foundation Upgrades: R-25 floor over vented crawlspace
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.230000004172
  • Window SHGC: 0.419999986887
  • Window Glazing Area: 52.0
  • Space Heating Type: Electric Resistance
  • Space Heating Capacity: 4.0
  • Space Heating Location: Other
  • Space Heating Energy Proto: 3.0
  • Space Heating Energy: 8.0
  • Space Heating Fuel: Electric
  • Space Heating Upgrades: Eccopanel mounted in room. This is prorated per unit energy use
  • Lighting Energy: 41.0
  • Lighting Energy Proto: 15.0
  • Light Appliance: 54.0
  • Light Appliance Proto: 36.0
  • Light Eff Type: 2
  • Light EEF Per: 80.0
  • MEL Load: 2
  • Cooling Type: None
  • Cooling Upgrades: the is prorated per unit energy use for no cooling
  • Duct Type: Ductless
  • Vent Type: Other
  • Vent Control: Continuous (24 hrs/day)
  • Vent Capacity: 30.0
  • IAQ Upgrades: w/dedicated make up air through trickle ventilators. rolled into miscellaneous
  • Hot Water Type: Solar assisted
  • Hot Water Backup: Heat pump
  • Hot Water Combustion: Not Applicable
  • Hot Water Location: Other
  • Hot Water Energy Proto: 3.0
  • Hot Water Energy: 39.0
  • Hot Water Fuel: Electric
  • Hot Water Upgrades: Central solar thermal system with HP backup and shared storage. System serves the whole building. Feeding 23 nano-lofts. this is prorated portion for a single unit.
  • Modeler's Name: Christine Backman
  • Other Awards: LEED Midrise
  • Benchmark Version: 2008
  • Total Energy Use: 143.0
  • Total Energy Use Proto: 57.0
  • Percent Energy Savings: 59.0
  • Total Energy Savings: 59.0
  • Site Gen: None

Data and Resources

Additional Info

Field Value
Author David Springer
Maintainer David Springer
Last Updated September 16, 2016, 22:27 (Etc/UTC)
Created September 16, 2016, 22:27 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Marine
City Sanf Franciso
State CA
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 1970-01-01
Project Actual End Date 1970-01-01
Completed House Count 1
Expected House Count 23
Energy Savings Percentage 33
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1

Dataset extent

Map data © OpenStreetMap contributors
Tiles by OpenStreetMap