East Fayette Street Project

Weather Info:

  • Location: Baltimore, MD
  • Elevation: 154.0
  • Fact: 0.819999992847
  • End Type: No
  • Regional Office: Philadelphia
  • Submitted: No
  • Approved: Yes
  • Modified: 2010-01-17
  • Stage: Completed
  • Visit: No

Specification 4672

  • Percent Energy Savings: 7
  • Submitted: No
  • Approved: No
  • Floor Plan: Unknown

Specification 4673

  • Percent Energy Savings: 29
  • Submitted: No
  • Approved: No
  • Editor: Srikanth Puttagunta
  • Modified: 2010-01-19 00:00:00
  • Floor Plan: Rowhouse - 3BR
  • Style: Single-family attached, site built
  • House Type: Prototype/Research House (G2)
  • Number of Stories: 2.0
  • Number of Bedrooms: 3
  • Floor Area: 1300.0
  • Basement Area: 600.0
  • Roof Framing: Flat
  • Roof Insulation: Fiberglass batt
  • Roof R Value: 38.0
  • Roof Radiant: No
  • Wall Framing: Wood - 2x6 - 16 in o.c.
  • Wall Insulation: Fiberglass batts
  • Wall R Value: 19.0
  • Wall Sheathing: XPS
  • Wall Sheathing R Value: 2.5
  • Wall Radiant: No
  • Foundation Type: Unconditioned basement
  • Foundation Insulation: Rigid foam
  • Foundation R Value: 10.0
  • Window Glazing: Double pane - clear
  • Window Framing: Vinyl
  • Window U Value: 0.330000013113
  • Window SHGC: 0.360000014305
  • Space Heating Type: Air Source Heat Pump
  • Space Heating Combustion: N/A
  • Space Heating Efficiency: 7.69999980927
  • Space Heating Efficiency Type: HSPF
  • Space Heating Location: Basement
  • Space Heating Energy Proto: 28.0
  • Space Heating Energy: 58.0
  • Space Heating Fuel: Electric
  • Lighting Energy: 19.0
  • Lighting Energy Proto: 5.0
  • Light Appliance: 59.0
  • Light Appliance Proto: 56.0
  • Light Eff Type: 2
  • Light EEF Per: 100.0
  • Cooling Type: Air Source Heat Pump
  • Cooling SEER: 13.5
  • Cooling Fuel: Electric
  • Cooling Energy Proto: 8.0
  • Cooling Energy: 18.0
  • Duct Type: Sheet metal / Flex
  • Duct Location: Partially in conditioned space
  • Duct R Value: 6.0
  • Air Distribution Location: Basement
  • Air Handler Motor: PSC
  • Vent Type: No ventilation strategy
  • Vent Control: Manual (by occupants)
  • Vent Capacity: 60.0
  • Hot Water Type: Electric resistance
  • Hot Water Backup: Other
  • Hot Water Combustion: Not Applicable
  • Hot Water Location: Basement
  • Hot Water Capacity: 52.0
  • Hot Water Efficiency: 0.920000016689
  • Hot Water Energy Proto: 40.0
  • Hot Water Energy: 42.0
  • Hot Water Fuel: Electric
  • Energy Star Rating: Yes
  • Benchmark Version: 2008
  • Total Energy Use: 198.0
  • Total Energy Use Proto: 138.0
  • Percent Energy Savings: 29.0
  • Total Energy Savings: 29.0

Data and Resources

Additional Info

Field Value
Author Srikanth Puttagunta
Maintainer Srikanth Puttagunta
Last Updated September 16, 2016, 22:25 (Etc/UTC)
Created September 16, 2016, 22:25 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Mixed - Humid
City Baltimore
State MD
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 1970-01-01
Project Actual End Date 1970-01-01
Completed House Count 9
Expected House Count 9
Energy Savings Percentage 18
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1

Dataset extent

Map data © OpenStreetMap contributors
Tiles by OpenStreetMap