Homes at Easthampton Meadow

  • End Type: No
  • Regional Office: Boston
  • Submitted: Yes
  • Approved: No
  • Modified: 2011-04-27
  • Visit: No

Specification 4855

  • Percent Energy Savings: 0
  • Submitted: No
  • Approved: No
  • Editor: Phil Kerrigan
  • Modified: 2011-04-27 12:15:00
  • Floor Plan: Farmhouse - Bsmt
  • Style: Single-family detached, site built
  • Number of Stories: 2.5
  • Number of Bedrooms: 3
  • Floor Area: 2200.0
  • Basement Area: 1100.0
  • Conditioned Volume: 76543.0
  • Surface Area: 76487.0
  • Roof Framing: Other
  • Roof Framing Other: rafters
  • Roof Insulation: Sprayed cellulose
  • Roof R Value: 60.0
  • Roof Radiant: No
  • Roof Upgrades: 1" cellulose
  • Wall Framing: Other
  • Wall Framing Other: doublse stud
  • Wall Insulation: Spray Foam
  • Wall R Value: 45.0
  • Wall Sheathing: N/A
  • Wall Radiant: No
  • Foundation Type: Conditioned basement
  • Foundation Construction: Poured concrete
  • Foundation Insulation: Other
  • Foundation Insulation Other: spray foam
  • Foundation R Value: 20.0
  • Slab Insulation: 30.0
  • Foundation Upgrades: 6" XPS
  • Window Glazing: Triple pane
  • Window Framing: Vinyl
  • Window U Value: 0.34
  • Window SHGC: 0.6
  • Window Glazing Area: 120.0
  • Space Heating Type: Air Source Heat Pump
  • Space Heating Combustion: N/A
  • Space Heating Capacity: 36.0
  • Space Heating Efficiency: 8.6
  • Space Heating Location: Attic
  • Space Heating Energy Proto: 4.8
  • Space Heating Energy: 11.4
  • Space Heating Fuel: Electric
  • Lighting Energy: 13.8
  • Lighting Energy Proto: 9.0
  • Light Appliance: 25.18
  • Light Appliance Proto: 17.6
  • Light MEL: 35.3
  • Light MEL Proto: 31.21
  • Light Eff Type: 2
  • Light EEF Per: 100.0
  • MEL Load: 1
  • Cooling Type: Air Source Heat Pump
  • Cooling Capacity: 3.0
  • Cooling SEER: 16.0
  • Cooling Fuel: Electric
  • Cooling Energy Proto: 15.97
  • Cooling Energy: 23.2
  • Duct Type: Ductless
  • Duct Location: N/A
  • Air Distribution Location: Interior closet
  • Air Tight Upgrades: spray foam, air drywall approach
  • Air Handler Motor: ECM/Variable Speed
  • Vent Type: Heat Recovery Ventilator (HRV)
  • Vent Control: Duty Cycle (some operation in every hour)
  • Vent Capacity: 150.0
  • Vent Fan Proto: 0.91
  • Vent Fan: 1.5
  • Vapor Barriers: housewrap flashing windows
  • Drainage Upgrades: housewrap, vented cladding etc.
  • Vapor IN: 2
  • Vapor EX: 3
  • Hot Water Type: Gas - tankless
  • Hot Water Backup: Other
  • Hot Water Combustion: Sealed combustion
  • Hot Water Location: Interior closet
  • Hot Water Capacity: 1.0
  • Hot Water Efficiency: 0.98
  • Hot Water Energy Proto: 21.5
  • Hot Water Energy: 29.5
  • Hot Water Fuel: Natural Gas
  • Energy Star Rating: Meets criteria but not labeled
  • HERS Rating 2006: 55.0
  • Modeler's Name: Philip Kerrigan Jr., PE
  • Benchmark Version: 10
  • Total Energy Use: 139.88
  • Total Energy Use Proto: 100.99
  • Percent Energy Savings: 27.8
  • Total Energy Savings: 27.8

Data and Resources

Additional Info

Field Value
Author Phil Kerrigan
Maintainer Phil Kerrigan
Last Updated September 16, 2016, 22:32 (Etc/UTC)
Created September 16, 2016, 22:32 (Etc/UTC)
Construction Type New Construction
Evaluation Level Community Scale
Climate Cold
City Easthampton
State MA
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 1970-01-01
Project Actual End Date 1970-01-01
Completed House Count 1
Expected House Count 2
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1

Dataset extent

Map data © OpenStreetMap contributors
Tiles by OpenStreetMap