Vision

  • End Type: Yes
  • Submitted: Yes
  • Approved: No
  • Modified: 2011-01-19
  • Visit: Yes

Specification 4820

  • Percent Energy Savings: 0
  • Submitted: Yes
  • Approved: No
  • Editor: Srikanth Puttagunta
  • Modified: 2011-01-19 14:23:00
  • Model Name: 2-story
  • Floor Plan: VISION
  • Style: Single-family detached, site built
  • Number of Stories: 2.0
  • Number of Bedrooms: 3
  • Floor Area: 2570.0
  • Basement Area: 0.0
  • Conditioned Volume: 25700.0
  • Surface Area: 6275.0
  • Roof Framing: Cathedral
  • Roof Insulation: Spray Foam
  • Roof R Value: 19.0
  • Roof Radiant: No
  • Wall Framing: Insulated concrete forms
  • Wall Insulation: Rigid foam
  • Wall R Value: 20.0
  • Wall Sheathing: N/A
  • Wall Sheathing R Value: 0.0
  • Wall Radiant: No
  • Foundation Type: Slab on grade
  • Foundation Construction: Poured concrete
  • Foundation Insulation: None
  • Foundation R Value: 0.01
  • Slab Insulation: 0.01
  • Window Glazing: Double pane - low-e
  • Window Framing: Aluminum with thermal break
  • Window U Value: 0.3
  • Window SHGC: 0.19
  • Window Glazing Area: 488.0
  • Space Heating Type: Gas furnace
  • Space Heating Combustion: Power vented
  • Space Heating Capacity: 48.0
  • Space Heating Efficiency: 95.0
  • Space Heating Location: Attic
  • Space Heating Energy Proto: 5.9
  • Space Heating Energy: 11.2
  • Space Heating Fuel: Gas
  • Lighting Energy: 24.0
  • Lighting Energy Proto: 14.0
  • Light Appliance: 29.0
  • Light Appliance Proto: 22.0
  • Light MEL: 39.0
  • Light MEL Proto: 39.0
  • Light Meas: 39.0
  • Light Meas Proto: 39.0
  • Light Eff Type: 2
  • Light EEF Per: 100.0
  • MEL Load: 1
  • Cooling Type: Electric Air Conditioner (split system)
  • Cooling Capacity: 4.0
  • Cooling SEER: 18.0
  • Cooling Fuel: Electric
  • Cooling Energy Proto: 23.0
  • Cooling Energy: 43.0
  • Duct Type: Sheet metal / Flex
  • Duct Location: In conditioned space
  • Duct R Value: 6.0
  • Air Distribution Location: Attic
  • Air Handler Motor: ECM/Variable Speed
  • Vent Type: Energy Recovery Ventilator (ERV)
  • Vent Control: Continuous (24 hrs/day)
  • Vent Capacity: 60.0
  • Vent Fan Proto: 1.93
  • Vent Fan: 3.21
  • Vapor Barriers: unknown
  • Vapor IN: 5
  • Vapor EX: 5
  • Hot Water Type: Solar assisted
  • Hot Water Backup: Gas - tank
  • Hot Water Combustion: Sealed combustion
  • Hot Water Location: Other
  • Hot Water Location Other: Attic (conditioned)
  • Hot Water Capacity: 120.0
  • Hot Water Efficiency: 3.2
  • Hot Water Energy Proto: 0.47
  • Hot Water Energy: 16.0
  • Hot Water Fuel: Natural Gas
  • Energy Star Rating: Meets criteria but not labeled
  • HERS Rating: 96
  • HERS Rating 2006: 46.0
  • Modeler's Name: Gayathri Vijayakumar
  • Benchmark Version: 2010
  • Total Energy Use: 204.41
  • Total Energy Use Proto: 145.3
  • Percent Energy Savings: 28.91
  • Total Energy Savings: 28.91
  • Site Gen: None

Data and Resources

Additional Info

Field Value
Author Srikanth Puttagunta
Maintainer Srikanth Puttagunta
Last Updated September 16, 2016, 22:31 (Etc/UTC)
Created September 16, 2016, 22:31 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Hot - Humid
City Orlando
State FL
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 1970-01-01
Project Actual End Date 1970-01-01
Completed House Count 1
Expected House Count 1
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1

Dataset extent

Map data © OpenStreetMap contributors
Tiles by OpenStreetMap