  • Ivy Gate at Loma Vista

    Description: R-19 walls (R-15 blown fiberglass plus R-4 foam sheathing) R-49 attic (floor) and Radiant barrer roof sheathing Windows- U .34, SHGC .26 Heating 94.7% AFUE forced...
  • Cambria Hills

    Description: Heating & cooling: 92% AFUE furnace, 14 SEER air conditioner Tight, R-8 ducts (<5% total leakage) in unconditioned attic ASHRAE 62.2 compliant with timed...
  • Ivy Gate at Loma vista

    Description: Heating & cooling: 94.7%. Bryant furnace/19.2 SEER air conditioner Very tight ducts (< 3% total leakage) Insulated to R-8 Jump ducts and transfer grill...
  • Golf Cottages

    Description: Ground-source heat pump tied to de-superheater for supplemental water heating; R-20 roof deck insulation in seealed, cathedralized attic. End Type: Yes Submitted:...
  • Golf Cottages

    Description: Sealed attic with R-20 insulated roof deck; Ground Source Heat Pump (GSHP) space conditioning tied to desuperheater for DHW pre-heating; R-3 XPS insulated...
  • Cibolo Canyons

    Description: Sealed attic with insulated (R-19) roof deck; 2x6", 24" o.c. OVE framing; 17 SEER heat pump; 94% AFUE gas furnace; solar thermal water heating; 2 kW photovoltaic...
  • New American Home 2011

    Description: The most noteworthy features of TNAH 2011 include the airtightness of its thermal shell and the use of solar energy for space conditioning and hot water. Under...
  • Kathryn Estates - TNAH2010

    Description: The exterior walls were constructed using a 10" thick insulated concrete form system with R-23 thermal performance with recycled polystyrene. All of the windows...
  • Urban Infill

    End Type: Yes Regional Office: Chicago Submitted: No Approved: Yes Modified: 2009-08-06 Stage: Completed Visit: No Specification 4577 Percent Energy Savings: 7 Submitted: No...
  • Stillwater Ranch

    Description: Cathedralized, sealed attic assembly; high efficiency heating and cooling system; tank-less natural gas water heater; low-density spray foam insulation in walls...
  • Marquis Las Vegas - TNAH2009

    Description: The home's three stories are conditioned using a gas-engine driven heat pump, mini split system. The system uses air handlers contained within the ceiling assembly...
  • Stapleton

    Description: 50% Energy reduction through: R-26 walls, R - 50 ceiling Under slab insulation 9.0 HPSF heat pump & 94% AFUE backup furnace 16.7 SEER A/C HRV ventilation...
  • Sunset Harbour

    Description: walls, attic, piers foundation, End Type: No Regional Office: Philadelphia Submitted: No Approved: Yes Modified: 2009-07-13 Stage: Design Visit: No Specification...
  • Eagles Pointe

    Description: Fully sheathed with R-3 Dow Structural Insulated Sheathing with 1" R-6.5 spray polyurethane foam insulation and R-15 kraft faced fiberglass batt in cavity;...
  • Greensburg, KS

    Description: Overview: Greensburg, KS suffered wide spread destruction when an EF-5 tornado, over one-mile wide, struck the city in early-May 2007; almost every structure in...
  • Venango Trails

    Description: Overview: All homes in EQA's Venango Trails community will be built to achieve a minimum level of 40% whole house energy savings.    Energy Efficient...
  • Montalbano Homes

    Description: Overview:   Key Partners:   Energy Efficiency Measures:   Other Features:   Weather Info: Location: Phoenix, AZ Elevation: 1106.0...
  • McStain Neighborhoods

    Description: Overview:   Key Partners:   Energy Efficiency Measures:   Other Features:   End Type: No Regional Office: Denver Submitted: No...
  • Harvest Park - Stonebrook

    Description: Overview: House is designed to reach the 40% energy savings level. Key Partners:   Energy Efficiency Measures: Poured concrete foundation, 4ft below...
  • Mount Desert Island

    Description: Overview: Proposed 30 unit community currently in the design and planning phase.  Key Partners: Coldham Architects and Bar Harbor Housing Authority...