Artistic Homes Portotypes

  • Description: OVE framing: R-21 wall insulationo, R-50 attic insulation,  0.31/0.31 U-value/SHGC windows,  9.0 HSPF, 15 SEER heat pump, Ducts inside conditioned space, Flat plate collector solar hot water with 80 gallon storage tank, Integrated photovoltaic and solar thermal panels with a 100 liter storage tank, 100% fluorescent lighting

Weather Info:

  • Location: Albuquerque, NM
  • Elevation: 5315.0
  • Fact: 0.800000011921
  • End Type: No
  • Regional Office: Denver
  • Submitted: No
  • Approved: Yes
  • Modified: 2010-01-19
  • Stage: Under Construction
  • Visit: No

Specification 4684

  • Percent Energy Savings: 7
  • Submitted: No
  • Approved: No
  • Floor Plan: Unknown

Specification 4685

  • Percent Energy Savings: 55
  • Submitted: No
  • Approved: No
  • Editor: Vicky Pang
  • Modified: 2010-01-19 09:46:00
  • Floor Plan: 2118
  • Style: Single-family detached, site built
  • House Type: Prototype/Research House (G2)
  • Number of Stories: 1.0
  • Number of Bedrooms: 3
  • Floor Area: 2118.0
  • Conditioned Volume: 16944.0
  • Roof R Value: 50.0
  • Roof Radiant: No
  • Wall Framing: Insulated concrete forms
  • Wall R Value: 21.0
  • Wall Radiant: No
  • Foundation Type: Slab on grade
  • Foundation R Value: 10.0
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.310000002384
  • Window SHGC: 0.310000002384
  • Space Heating Type: Air Source Heat Pump
  • Space Heating Efficiency: 9.0
  • Space Heating Efficiency Type: HSPF
  • Space Heating Energy Proto: 31.0
  • Space Heating Energy: 121.0
  • Space Heating Fuel: Electric
  • Lighting Energy: 27.0
  • Lighting Energy Proto: 8.0
  • Light Appliance: 64.0
  • Light Appliance Proto: 62.0
  • Light Eff Type: 2
  • Light EEF Per: 100.0
  • Renewable Energy Offset: 5.0
  • Cooling Type: Air Source Heat Pump
  • Cooling SEER: 15.0
  • Cooling Fuel: Electric
  • Cooling Energy Proto: 6.0
  • Cooling Energy: 38.0
  • Duct Location: In conditioned space
  • Duct R Value: 8.0
  • Vent Type: Balanced supply and exhaust
  • Vent Fan Proto: 16.0
  • Vent Fan: 2.0
  • IAQ Upgrades: 100% ASHRAE 62.2
  • Hot Water Type: Solar assisted
  • Hot Water Capacity: 80.0
  • Hot Water Efficiency: 0.899999976158
  • Hot Water Energy Proto: 6.0
  • Hot Water Energy: 42.0
  • Hot Water Fuel: Electric
  • Energy Star Rating: Yes
  • Total Energy Use: 295.0
  • Total Energy Use Proto: 131.0
  • Percent Site Energy: 1.0
  • Total Energy Savings: 57.0
  • Site Gen: PV
  • SG Capacity: 5.7

Specification 4686

  • Percent Energy Savings: 56
  • Submitted: No
  • Approved: Yes
  • Editor: Vicky Pang
  • Modified: 2010-01-19 00:00:00
  • Floor Plan: 1008
  • Style: Single-family detached, site built
  • House Type: Prototype/Research House (G2)
  • Number of Stories: 1.0
  • Number of Bedrooms: 2
  • Floor Area: 1008.0
  • Conditioned Volume: 8064.0
  • Roof R Value: 50.0
  • Roof Radiant: No
  • Wall Framing: Insulated concrete forms
  • Wall R Value: 21.0
  • Wall Radiant: No
  • Foundation Type: Slab on grade
  • Foundation R Value: 10.0
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.310000002384
  • Window SHGC: 0.310000002384
  • Space Heating Type: Air Source Heat Pump
  • Space Heating Efficiency: 9.0
  • Space Heating Efficiency Type: HSPF
  • Space Heating Energy Proto: 27.0
  • Space Heating Energy: 98.0
  • Space Heating Fuel: Electric
  • Lighting Energy: 18.0
  • Lighting Energy Proto: 5.0
  • Light Appliance: 53.0
  • Light Appliance Proto: 54.0
  • Light Eff Type: 2
  • Light EEF Per: 100.0
  • Renewable Energy Offset: 5.0
  • Cooling Type: Air Source Heat Pump
  • Cooling SEER: 15.0
  • Cooling Fuel: Electric
  • Cooling Energy Proto: 3.0
  • Cooling Energy: 15.0
  • Duct Location: In conditioned space
  • Duct R Value: 8.0
  • Vent Type: Balanced supply and exhaust
  • Vent Fan Proto: 4.0
  • Vent Fan: 1.0
  • IAQ Upgrades: 100% ASHRAE 62.2
  • Hot Water Type: Solar assisted
  • Hot Water Capacity: 100.0
  • Hot Water Efficiency: 0.949999988079
  • Hot Water Energy Proto: 2.0
  • Hot Water Energy: 39.0
  • Hot Water Fuel: Electric
  • Energy Star Rating: Yes
  • Total Energy Use: 226.0
  • Total Energy Use Proto: 97.0
  • Percent Energy Savings: 56.0
  • Percent Site Energy: 2.0
  • Total Energy Savings: 59.0
  • Site Gen: PV
  • SG Capacity: 5.7

Data and Resources

Additional Info

Field Value
Author Vicky Pang
Maintainer Vicky Pang
Last Updated September 16, 2016, 22:26 (Etc/UTC)
Created September 16, 2016, 22:26 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Hot - Dry
City Albuquerque
State NM
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 1970-01-01
Project Actual End Date 1970-01-01
Completed House Count 1
Expected House Count 2
Energy Savings Percentage 39
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1

Dataset extent

Map data © OpenStreetMap contributors
Tiles by OpenStreetMap