Avalon

Weather Info:

  • Location: Albuquerque, NM
  • Elevation: 5315.0
  • Fact: 0.800000011921
  • End Type: No
  • Regional Office: Denver
  • Submitted: No
  • Approved: Yes
  • Modified: 2008-05-05
  • Visit: No

Specification 195

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: Marcia Fratello
  • Modified: 2003-05-22 00:00:00
  • Model Name: 1
  • Floor Plan: Plan 1 (Avalon)
  • House Type: Production (G3)
  • Number of Stories: 1.0
  • Floor Area: 1357.0
  • Conditioned Volume: 12052.0
  • Surface Area: 2852.0
  • Roof Framing: Unvented attic - truss framing
  • Roof Insulation: Fiberglass blown
  • Roof R Value: 38.0
  • Roof Radiant: No
  • Wall R Value: 19.0
  • Wall Radiant: No
  • Wall Upgrades: Wood, 2x6, 24 in o.c. w/asphalt impregnated sheathing Sheath + Cavity
  • Foundation Type: Slab on grade
  • Foundation Insulation: Rigid foam
  • Slab Insulation: 5.0
  • Foundation Upgrades: Perimeter slab insulation
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.360000014305
  • Window SHGC: 0.449999988079
  • Space Heating Type: Hot water combo
  • Space Heating Efficiency: 75.0
  • Space Heating Efficiency Type: % AFUE
  • Space Heating Location: Garage
  • Cooling Type: Electric Air Conditioner (split system)
  • Cooling Capacity: 1.5
  • Cooling SEER: 10.0
  • Duct Type: Sheet metal
  • Duct Location: In conditioned space
  • Air Distribution Location: Attic
  • Air Tight Upgrades: 2.5 sq in / 100 sq ft leakage
  • Vent Type: Controlled supply
  • Vent Control: Duty Cycle (some operation in every hour)
  • IAQ Upgrades: AirCycler supply ventilation system supplies outside air continuously.
  • Hot Water Type: Gas - tank
  • Hot Water Location: Garage
  • Hot Water Capacity: 40.0
  • Hot Water Efficiency: 0.569999992847
  • Energy Star Rating: Yes
  • HERS Rating: 88
  • Total Energy Savings: 15.0

Specification 196

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: Marcia Fratello
  • Modified: 2003-05-22 00:00:00
  • Model Name: 10
  • Floor Plan: Plan 10 (Avalon)
  • House Type: Production (G3)
  • Number of Stories: 1.0
  • Floor Area: 1344.0
  • Conditioned Volume: 11643.0
  • Surface Area: 2648.0
  • Roof Framing: Unvented attic - truss framing
  • Roof Insulation: Fiberglass blown
  • Roof R Value: 38.0
  • Roof Radiant: No
  • Wall R Value: 19.0
  • Wall Radiant: No
  • Wall Upgrades: Wood, 2x6, 24 in o.c. w/asphalt impregnated sheathing Sheath + Cavity
  • Foundation Type: Slab on grade
  • Foundation Insulation: Rigid foam
  • Slab Insulation: 5.0
  • Foundation Upgrades: Perimeter slab insulation
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.360000014305
  • Window SHGC: 0.449999988079
  • Space Heating Type: Hot water combo
  • Space Heating Efficiency: 75.0
  • Space Heating Efficiency Type: % AFUE
  • Space Heating Location: N/A
  • Cooling Type: Electric Air Conditioner (split system)
  • Cooling Capacity: 1.5
  • Cooling SEER: 10.0
  • Duct Type: Sheet metal
  • Duct Location: In conditioned space
  • Air Distribution Location: Attic
  • Air Tight Upgrades: 2.5 sq in / 100 sq ft leakage
  • Vent Type: Controlled supply
  • Vent Control: Duty Cycle (some operation in every hour)
  • IAQ Upgrades: AirCycler supply ventilation system supplies outside air continuously.
  • Hot Water Type: Gas - tank
  • Hot Water Location: Garage
  • Hot Water Capacity: 40.0
  • Hot Water Efficiency: 0.569999992847
  • Energy Star Rating: Yes
  • HERS Rating: 88
  • Total Energy Savings: 15.0

Specification 197

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: Marcia Fratello
  • Modified: 2003-05-22 00:00:00
  • Model Name: 50
  • Floor Plan: Plan 50 (Avalon)
  • House Type: Production (G3)
  • Number of Stories: 1.0
  • Floor Area: 1631.0
  • Conditioned Volume: 14244.0
  • Surface Area: 3387.0
  • Roof Framing: Unvented attic - truss framing
  • Roof Insulation: Fiberglass blown
  • Roof R Value: 38.0
  • Roof Radiant: No
  • Wall R Value: 19.0
  • Wall Radiant: No
  • Wall Upgrades: Wood, 2x6, 24 in o.c. w/asphalt impregnated sheathing Sheath + Cavity
  • Foundation Type: Slab on grade
  • Foundation Insulation: Rigid foam
  • Slab Insulation: 5.0
  • Foundation Upgrades: Perimeter slab insulation
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.360000014305
  • Window SHGC: 0.449999988079
  • Space Heating Type: Hot water combo
  • Space Heating Efficiency: 75.0
  • Space Heating Efficiency Type: % AFUE
  • Space Heating Location: Garage
  • Cooling Type: Electric Air Conditioner (split system)
  • Cooling Capacity: 1.5
  • Cooling SEER: 10.0
  • Duct Type: Sheet metal
  • Duct Location: In conditioned space
  • Air Distribution Location: Attic
  • Air Tight Upgrades: 2.5 sq in / 100 sq ft leakage
  • Vent Type: Controlled supply
  • Vent Control: Duty Cycle (some operation in every hour)
  • IAQ Upgrades: AirCycler supply ventilation system supplies outside air continuously.
  • Hot Water Type: Gas - tank
  • Hot Water Location: Garage
  • Hot Water Capacity: 40.0
  • Hot Water Efficiency: 0.569999992847
  • Energy Star Rating: Yes
  • HERS Rating: 88
  • Total Energy Savings: 15.0

Specification 198

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: Marcia Fratello
  • Modified: 2003-05-22 00:00:00
  • Model Name: 26
  • Floor Plan: Plan 26 (Avalon)
  • House Type: Production (G3)
  • Number of Stories: 1.0
  • Floor Area: 1531.0
  • Conditioned Volume: 12785.0
  • Surface Area: 3159.0
  • Roof Framing: Unvented attic - truss framing
  • Roof Insulation: Fiberglass blown
  • Roof R Value: 38.0
  • Roof Radiant: No
  • Wall R Value: 19.0
  • Wall Radiant: No
  • Wall Upgrades: Wood, 2x6, 24 in o.c. w/asphalt impregnated sheathing Sheath + Cavity
  • Foundation Type: Slab on grade
  • Foundation Insulation: Rigid foam
  • Slab Insulation: 5.0
  • Foundation Upgrades: Perimeter slab insulation
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.360000014305
  • Window SHGC: 0.449999988079
  • Space Heating Type: Hot water combo
  • Space Heating Efficiency: 75.0
  • Space Heating Efficiency Type: % AFUE
  • Space Heating Location: N/A
  • Cooling Type: Electric Air Conditioner (split system)
  • Cooling Capacity: 1.5
  • Cooling SEER: 10.0
  • Duct Type: Sheet metal
  • Duct Location: In conditioned space
  • Air Distribution Location: Attic
  • Air Tight Upgrades: 2.5 sq in / 100 sq ft leakage
  • Vent Type: Controlled supply
  • Vent Control: Duty Cycle (some operation in every hour)
  • IAQ Upgrades: AirCycler supply ventilation system supplies outside air continuously.
  • Hot Water Type: Gas - tank
  • Hot Water Location: Garage
  • Hot Water Capacity: 40.0
  • Hot Water Efficiency: 0.569999992847
  • Energy Star Rating: Yes
  • HERS Rating: 88
  • Total Energy Savings: 15.0

Specification 199

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: Marcia Fratello
  • Modified: 2003-05-22 00:00:00
  • Model Name: 12
  • Floor Plan: Plan 12 (Avalon)
  • House Type: Production (G3)
  • Number of Stories: 1.0
  • Floor Area: 1412.0
  • Conditioned Volume: 12695.0
  • Surface Area: 2952.0
  • Roof Insulation: Fiberglass blown
  • Roof R Value: 38.0
  • Roof Radiant: No
  • Roof Upgrades: Vented assembly, baffles at eaves to maintian minimum 1" vent space under roof deck and to block wind washing of insulation
  • Wall R Value: 19.0
  • Wall Sheathing: Other
  • Wall Sheathing R Value: 4.0
  • Wall Radiant: No
  • Wall Upgrades: Asphalt impregnated fiberboard and OSB exterior sheathing
  • Foundation Type: Slab on grade
  • Foundation Insulation: Rigid foam
  • Slab Insulation: 5.0
  • Foundation Upgrades: Perimeter slab insulation
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.360000014305
  • Window SHGC: 0.449999988079
  • Space Heating Type: Hot water combo
  • Space Heating Efficiency: 75.0
  • Space Heating Efficiency Type: % AFUE
  • Space Heating Upgrades: combination space and domestic hot water system in conditioned space
  • Cooling Type: Evaporative cooling
  • Cooling Capacity: 1.5
  • Cooling SEER: 12.0
  • Cooling Upgrades: 2.0 Ton evaporator coil inside aquatherm air handler unit with Rheem outdoor condensing unit
  • Duct Type: Sheet metal
  • Duct Location: In conditioned space
  • Air Distribution Location: Attic
  • Air Tight Upgrades: 2.5 sq in / 100 sq ft leakage
  • Vent Type: Controlled supply
  • Vent Control: Duty Cycle (some operation in every hour)
  • IAQ Upgrades: AirCycler supply ventilation system supplies outside air continuously.
  • Hot Water Type: Gas - tank
  • Hot Water Combustion: Sealed combustion
  • Hot Water Location: Garage
  • Hot Water Capacity: 40.0
  • Hot Water Efficiency: 0.569999992847
  • HERS Rating: 88
  • Total Energy Savings: 15.0

Specification 200

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: Marcia Fratello
  • Modified: 2003-05-22 00:00:00
  • Model Name: 54
  • Floor Plan: Plan 54 (Avalon)
  • House Type: Production (G3)
  • Number of Stories: 1.0
  • Floor Area: 1737.0
  • Conditioned Volume: 14634.0
  • Surface Area: 3562.0
  • Roof Framing: Unvented attic - truss framing
  • Roof Insulation: Fiberglass blown
  • Roof R Value: 38.0
  • Roof Radiant: No
  • Wall R Value: 19.0
  • Wall Radiant: No
  • Wall Upgrades: Wood, 2x6, 24 in o.c. w/asphalt impregnated sheathing Sheath + Cavity
  • Foundation Type: Slab on grade
  • Foundation Insulation: Rigid foam
  • Slab Insulation: 5.0
  • Foundation Upgrades: Perimeter slab insulation
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.360000014305
  • Window SHGC: 0.449999988079
  • Space Heating Type: Hot water combo
  • Space Heating Efficiency: 75.0
  • Space Heating Efficiency Type: % AFUE
  • Cooling Type: Electric Air Conditioner (split system)
  • Cooling Capacity: 1.5
  • Cooling SEER: 10.0
  • Duct Type: Sheet metal
  • Duct Location: In conditioned space
  • Air Distribution Location: Attic
  • Air Tight Upgrades: 2.5 sq in / 100 sq ft leakage
  • Vent Type: Controlled supply
  • Vent Control: Duty Cycle (some operation in every hour)
  • IAQ Upgrades: AirCycler supply ventilation system supplies outside air continuously.
  • Hot Water Type: Gas - tank
  • Hot Water Location: Garage
  • Hot Water Capacity: 40.0
  • Hot Water Efficiency: 0.569999992847
  • Energy Star Rating: Yes
  • HERS Rating: 88
  • Total Energy Savings: 15.0

Specification 202

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: Marcia Fratello
  • Modified: 2003-05-22 00:00:00
  • Model Name: 55
  • Floor Plan: Plan 55 (Avalon)
  • House Type: Production (G3)
  • Number of Stories: 1.0
  • Floor Area: 1745.0
  • Conditioned Volume: 15479.0
  • Surface Area: 3526.0
  • Roof Framing: Unvented attic - truss framing
  • Roof Insulation: Fiberglass blown
  • Roof R Value: 38.0
  • Roof Radiant: No
  • Wall R Value: 19.0
  • Wall Radiant: No
  • Wall Upgrades: Wood, 2x6, 24 in o.c. w/asphalt impregnated sheathing Sheath + Cavity
  • Foundation Type: Slab on grade
  • Foundation Insulation: Rigid foam
  • Slab Insulation: 5.0
  • Foundation Upgrades: Perimeter slab insulation
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.360000014305
  • Window SHGC: 0.449999988079
  • Space Heating Type: Hot water combo
  • Space Heating Efficiency: 75.0
  • Space Heating Efficiency Type: % AFUE
  • Space Heating Location: Garage
  • Cooling Type: Electric Air Conditioner (split system)
  • Cooling Capacity: 1.5
  • Cooling SEER: 10.0
  • Duct Type: Sheet metal
  • Duct Location: In conditioned space
  • Air Distribution Location: Attic
  • Air Tight Upgrades: 2.5 sq in / 100 sq ft leakage
  • Vent Type: Controlled supply
  • Vent Control: Duty Cycle (some operation in every hour)
  • IAQ Upgrades: AirCycler supply ventilation system supplies outside air continuously.
  • Hot Water Type: Gas - tank
  • Hot Water Location: Garage
  • Hot Water Capacity: 40.0
  • Hot Water Efficiency: 0.569999992847
  • Energy Star Rating: Yes
  • HERS Rating: 88
  • Total Energy Savings: 15.0

Specification 203

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: Marcia Fratello
  • Modified: 2003-05-22 00:00:00
  • Model Name: 52
  • Floor Plan: Plan 52 (Avalon)
  • House Type: Production (G3)
  • Number of Stories: 1.0
  • Floor Area: 1691.0
  • Conditioned Volume: 13882.0
  • Surface Area: 3307.0
  • Roof Framing: Unvented attic - truss framing
  • Roof Insulation: Fiberglass blown
  • Roof R Value: 38.0
  • Roof Radiant: No
  • Wall R Value: 19.0
  • Wall Radiant: No
  • Wall Upgrades: Wood, 2x6, 24 in o.c. w/asphalt impregnated sheathing Sheath + Cavity
  • Foundation Type: Slab on grade
  • Foundation Insulation: Rigid foam
  • Slab Insulation: 5.0
  • Foundation Upgrades: Perimeter slab insulation
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.360000014305
  • Window SHGC: 0.449999988079
  • Space Heating Type: Hot water combo
  • Space Heating Efficiency: 75.0
  • Space Heating Efficiency Type: % AFUE
  • Space Heating Location: Garage
  • Cooling Type: Electric Air Conditioner (split system)
  • Cooling Capacity: 1.5
  • Cooling SEER: 10.0
  • Duct Type: Sheet metal
  • Duct Location: In conditioned space
  • Air Distribution Location: Attic
  • Air Tight Upgrades: 2.5 sq in / 100 sq ft leakage
  • Vent Type: Controlled supply
  • Vent Control: Duty Cycle (some operation in every hour)
  • IAQ Upgrades: AirCycler supply ventilation system supplies outside air continuously.
  • Hot Water Type: Gas - tank
  • Hot Water Location: Garage
  • Hot Water Capacity: 40.0
  • Hot Water Efficiency: 0.569999992847
  • Energy Star Rating: Yes
  • HERS Rating: 88
  • Total Energy Savings: 15.0

Specification 926

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Modified: 2008-05-05 00:00:00
  • Floor Plan: Unknown
  • House Type: Unknown
  • Roof Radiant: No
  • Wall Radiant: No
  • Total Energy Savings: 15.0

Data and Resources

Additional Info

Field Value
Author John Chase
Maintainer John Chase
Last Updated September 16, 2016, 20:41 (Etc/UTC)
Created September 16, 2016, 20:41 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Mixed - Dry
City Albuquerque
State NM
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 1970-01-01
Project Actual End Date 1970-01-01
Completed House Count 185
Expected House Count 185
Energy Savings Percentage 15
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1

Dataset extent