Borrego Springs

  • End Type: No
  • Regional Office: Seattle
  • Submitted: No
  • Approved: Yes
  • Modified: 2008-08-13
  • Stage: Under Construction
  • Visit: No

Specification 4415

  • Percent Energy Savings: 7
  • Submitted: No
  • Approved: No
  • Floor Plan: Unknown
  • Wall Radiant: No

Specification 4418

  • Percent Energy Savings: 43
  • Submitted: No
  • Approved: Yes
  • Editor: Vicky Pang
  • Modified: 2008-08-13 00:00:00
  • Floor Plan: SIP
  • House Type: Unknown
  • Wall Radiant: No
  • Space Heating Energy Proto: 2842.0
  • Space Heating Energy: 3130.0
  • Lighting Energy: 23969.0
  • Lighting Energy Proto: 7191.0
  • Light Appliance: 59213.0
  • Light Appliance Proto: 58643.0
  • Cooling Energy Proto: 44640.0
  • Cooling Energy: 119981.0
  • Hot Water Energy Proto: 15283.0
  • Hot Water Energy: 21941.0
  • Total Energy Use: 228234.0
  • Total Energy Use Proto: 128599.0
  • Percent Energy Savings: 43.0
  • Total Energy Savings: 43.0
  • Site Gen: PV

Specification 4419

  • Percent Energy Savings: 51
  • Submitted: No
  • Approved: No
  • Editor: Vicky Pang
  • Modified: 2008-08-13 17:09:00
  • Floor Plan: OVE
  • House Type: Unknown
  • Wall Radiant: No
  • Space Heating Energy Proto: 3629.0
  • Space Heating Energy: 15245.0
  • Lighting Energy: 23969.0
  • Lighting Energy Proto: 7197.0
  • Light Appliance: 59213.0
  • Light Appliance Proto: 58643.0
  • Cooling Energy Proto: 49440.0
  • Cooling Energy: 155232.0
  • Hot Water Energy Proto: 15285.0
  • Hot Water Energy: 24941.0
  • Total Energy Use: 278600.0
  • Total Energy Use Proto: 134194.0
  • Site Gen: PV

Specification 4420

  • Percent Energy Savings: 46
  • Submitted: No
  • Approved: No
  • Editor: Vicky Pang
  • Modified: 2008-08-13 17:19:00
  • Floor Plan: Tmass 1
  • House Type: Unknown
  • Wall Radiant: No
  • Space Heating Energy Proto: 1267.0
  • Space Heating Energy: 5856.0
  • Lighting Energy: 21717.0
  • Lighting Energy Proto: 10239.0
  • Light Appliance: 56988.0
  • Light Appliance Proto: 55192.0
  • Cooling Energy Proto: 29955.0
  • Cooling Energy: 98453.0
  • Hot Water Energy Proto: 13703.0
  • Hot Water Energy: 23622.0
  • Total Energy Use: 206636.0
  • Total Energy Use Proto: 110356.0
  • Site Gen: PV

Specification 4421

  • Percent Energy Savings: 53
  • Submitted: No
  • Approved: No
  • Editor: Vicky Pang
  • Modified: 2008-08-13 17:20:00
  • Floor Plan: Tmass 2
  • House Type: Unknown
  • Wall Radiant: No
  • Space Heating Energy Proto: 836.0
  • Space Heating Energy: 16198.0
  • Lighting Energy: 24952.0
  • Lighting Energy Proto: 7486.0
  • Light Appliance: 61265.0
  • Light Appliance Proto: 60695.0
  • Cooling Energy Proto: 51163.0
  • Cooling Energy: 164934.0
  • Hot Water Energy Proto: 15708.0
  • Hot Water Energy: 26500.0
  • Total Energy Use: 293849.0
  • Total Energy Use Proto: 135888.0
  • Site Gen: PV

Data and Resources

Additional Info

Field Value
Author Vicky Pang
Maintainer Vicky Pang
Last Updated September 16, 2016, 22:15 (Etc/UTC)
Created September 16, 2016, 22:15 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Hot - Dry
City Borrego Springs
State CA
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 1970-01-01
Project Actual End Date 1970-01-01
Completed House Count 4
Expected House Count 16
Energy Savings Percentage 40
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1