Cambria Hills

  • Description: Heating & cooling: 92% AFUE furnace, 14 SEER air conditioner Tight, R-8 ducts (<5% total leakage) in unconditioned attic ASHRAE 62.2 compliant with timed whole house exhaust Enclosure: R-13 blown cellulouse plus 1" EPS continuous sheathing, R-38 attic floor plus radiant barrier roof sheathing. Tight construction (<2.5 ACH50) Windows: U-.31, SHGC - .26 Domestic hot water: Tankless gas, EF .82 All Energy Star Appliances 90% florescent or cfl lighting
  • End Type: No
  • Regional Office: Seattle
  • Submitted: No
  • Approved: No
  • Modified: 2010-04-29
  • Stage: Planning
  • Visit: No

Specification 4779

  • Percent Energy Savings: 7
  • Submitted: No
  • Approved: No
  • Floor Plan: Unknown

Data and Resources

Additional Info

Field Value
Author Graham Davis
Maintainer Graham Davis
Last Updated September 16, 2016, 22:30 (Etc/UTC)
Created September 16, 2016, 22:29 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Hot - Dry
City Lake Elsinore
State CA
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 2010-09-15
Project Actual End Date 2010-09-15
Completed House Count 1
Expected House Count 1
Energy Savings Percentage 7
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1