Edmund Park

  • Description: Hedgewood wants every home they build to meet or exceed the U.S. Environmental Protection Agency's ENERGY STARâ„¢ criteria. Several homes have been built to this level, but they want a way of doing it so that it can be easily replicated with minimal cost impact. This objective resulted in any examination of design and construction practices and the building of a pilot home. Features iinclude plywood sheathing was placed across the floor of the third floor, polyurethane foam was used to seal any gaps in the decking, high-performance windows with U=0.33 and solar heat gain coefficient of 0.32 were installed, air handler systems had ventilation lines connected to them and a ventilation controller was used so that the blower was set to run for enough time to ensure adequate distribution of outdoor air, and crawlspace walls are insulated with batts and all penetrations and gaps in the wall are foam sealed or caulked.

Weather Info:

  • Location: Atlanta, GA
  • Elevation: 1033.0
  • Fact: 0.75
  • End Type: No
  • Regional Office: Atlanta
  • Submitted: No
  • Approved: Yes
  • Modified: 2008-05-05
  • Visit: No

Specification 798

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Modified: 2008-05-05 00:00:00
  • Model Name: Edmund Park
  • Floor Plan: Edmund Park
  • House Type: Prototype/Research House (G2)
  • Number of Stories: 3.0
  • Number of Bedrooms: 3
  • Conditioned Volume: 40943.0
  • Roof Framing: Vented attic - truss framing
  • Roof Insulation: Fiberglass blown
  • Roof R Value: 30.0
  • Roof Radiant: No
  • Wall Insulation: Fiberglass batts
  • Wall R Value: 13.0
  • Wall Radiant: No
  • Wall Upgrades: Draft stopping sheathing
  • Foundation Type: Unvented crawl space
  • Foundation Insulation: Fiberglass batts
  • Foundation R Value: 13.0
  • Foundation Upgrades: Crawl space walls insulated
  • Window Glazing: Double pane - low-e
  • Window Framing: Wood
  • Window U Value: 0.330000013113
  • Window SHGC: 0.319999992847
  • Space Heating Type: Gas furnace
  • Space Heating Combustion: Naturally Vented
  • Space Heating Capacity: 100000.0
  • Space Heating Efficiency: 81.0
  • Space Heating Efficiency Type: % AFUE
  • Space Heating Location: Other
  • Space Heating Upgrades: Two units (crawl space and interior closet)
  • Cooling Type: Electric Air Conditioner (split system)
  • Cooling Capacity: 4.0
  • Cooling SEER: 12.0
  • Cooling Upgrades: Higher efficiency
  • Duct Type: Flexible
  • Duct Location: In conditioned space
  • Duct R Value: 4.19999980927
  • Air Distribution Location: Other
  • Air Distribution Upgrades: Two air handlers (crawl space and closet). All ducts brought inside
  • Air Tight Upgrades: Sealing Penetrations,draftstopping
  • Vent Type: Controlled supply
  • Vent Control: Duty Cycle (some operation in every hour)
  • Vent Capacity: 150.0
  • IAQ Upgrades: Two controlled supply
  • Hot Water Type: Gas - tank
  • Hot Water Combustion: Power vented
  • Hot Water Location: Interior closet
  • Hot Water Capacity: 50.0
  • Hot Water Efficiency: 0.560000002384
  • Energy Star Rating: Yes
  • Total Energy Savings: 15.0

Specification 845

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Modified: 2008-05-05 00:00:00
  • Floor Plan: Unknown
  • House Type: Unknown
  • Roof Radiant: No
  • Wall Radiant: No
  • Total Energy Savings: 15.0

Data and Resources

Additional Info

Field Value
Author John Chase
Maintainer John Chase
Last Updated September 16, 2016, 20:23 (Etc/UTC)
Created September 16, 2016, 20:23 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Mixed - Humid
City Atlanta
State GA
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 1970-01-01
Project Actual End Date 1970-01-01
Completed House Count 1
Expected House Count 1
Energy Savings Percentage 15
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1