Habitat For Humanity

Weather Info:

  • Location: Tampa, FL
  • Elevation: 10.0
  • Fact: 0.75
  • End Type: Yes
  • Regional Office: Atlanta
  • Submitted: No
  • Approved: No
  • Modified: 2010-04-30
  • Stage: Completed
  • Visit: No

Specification 4781

  • Percent Energy Savings: 7
  • Submitted: No
  • Approved: No
  • Floor Plan: Unknown

Specification 4782

  • Percent Energy Savings: 37
  • Submitted: No
  • Approved: No
  • Editor: Bob Abernethy
  • Modified: 2010-04-30 07:38:00
  • Model Name: HFH-1149
  • Floor Plan: HFH-2624
  • Style: Single-family detached, site built
  • House Type: Production (G3)
  • Number of Stories: 1.0
  • Number of Bedrooms: 3
  • Floor Area: 1149.0
  • Conditioned Volume: 9192.0
  • Roof Framing: Vented attic - truss framing
  • Roof Insulation: Fiberglass blown
  • Roof R Value: 30.0
  • Roof Radiant: No
  • Wall Framing: Wood - 2x4 - 16 in o.c.
  • Wall Insulation: Fiberglass batts
  • Wall R Value: 15.0
  • Wall Radiant: No
  • Foundation Type: Slab on grade
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.319999992847
  • Window SHGC: 0.280000001192
  • Window Glazing Area: 99.0
  • Space Heating Type: Air Source Heat Pump
  • Space Heating Capacity: 28.0
  • Space Heating Efficiency: 8.0
  • Space Heating Efficiency Type: HSPF
  • Space Heating Location: Interior closet
  • Space Heating Energy Proto: 1.0
  • Space Heating Energy: 6.0
  • Space Heating Fuel: Electric
  • Lighting Energy: 18.0
  • Lighting Energy Proto: 15.0
  • Light Appliance: 57.0
  • Light Appliance Proto: 53.0
  • Light Eff Type: 2
  • Light EEF Per: 33.0
  • Cooling Type: Air Source Heat Pump
  • Cooling Capacity: 2.5
  • Cooling SEER: 14.0
  • Cooling Fuel: Electric
  • Cooling Energy Proto: 24.0
  • Cooling Energy: 83.0
  • Duct Type: Duct Board / Flex
  • Duct Location: In unconditioned space
  • Duct R Value: 6.0
  • Air Distribution Location: Interior closet
  • Air Handler Motor: ECM/Variable Speed
  • Vent Type: Central fan integrated supply
  • Vent Control: Thermostat (concurrent with heating/cooling)
  • Hot Water Type: Electric resistance
  • Hot Water Location: Interior closet
  • Hot Water Capacity: 40.0
  • Hot Water Efficiency: 0.920000016689
  • Hot Water Energy Proto: 26.0
  • Hot Water Energy: 29.0
  • Hot Water Fuel: Electric
  • Energy Star Rating: Yes
  • HERS Rating: 91
  • HERS Rating 2006: 68.0
  • Modeler's Name: Bob Abernethy
  • Benchmark Version: 2008
  • Total Energy Use: 195.0
  • Total Energy Use Proto: 122.0
  • Total Energy Savings: 37.0

Data and Resources

Additional Info

Field Value
Author Bob Abernethy
Maintainer Bob Abernethy
Last Updated September 16, 2016, 22:30 (Etc/UTC)
Created September 16, 2016, 22:30 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Hot - Humid
City Tampa
State FL
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 1970-01-01
Project Actual End Date 1970-01-01
Completed House Count 1
Expected House Count 1
Energy Savings Percentage 22
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1

Dataset extent

Map data © OpenStreetMap contributors
Tiles by OpenStreetMap