Mololani Prototype

  • Description: Metal framing: R-15 wall insulationo, R-25 attic insulation, 0.35/0.23 U-value/SHGC windows, 16 SEER HVAC unit, Ducts either buried or inside conditioned space (cathedralized attic), 80 gal. solar hot water with 5 kW backup, 100% fluorescent lighting, Verve (Whole house lighting and outlet control system) and ENERGY STAR appliances
  • End Type: No
  • Regional Office: Seattle
  • Submitted: No
  • Approved: Yes
  • Modified: 2010-01-19
  • Stage: Under Construction
  • Visit: No

Specification 4689

  • Percent Energy Savings: 7
  • Submitted: No
  • Approved: No
  • Floor Plan: Unknown

Specification 4690

  • Percent Energy Savings: 52
  • Submitted: No
  • Approved: No
  • Editor: Vicky Pang
  • Modified: 2010-01-19 10:20:00
  • Floor Plan: 110
  • Style: Single-family attached, site built
  • House Type: Prototype/Research House (G2)
  • Number of Stories: 2.0
  • Number of Bedrooms: 3
  • Floor Area: 1693.0
  • Conditioned Volume: 15237.0
  • Roof Framing: Vented attic - truss framing
  • Roof Insulation: Sprayed cellulose
  • Roof R Value: 25.0
  • Roof Radiant: No
  • Wall Framing: Steel frame - 4 in.
  • Wall Insulation: Fiberglass batts
  • Wall R Value: 13.0
  • Wall Radiant: No
  • Foundation Type: Slab on grade
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.34999999404
  • Window SHGC: 0.230000004172
  • Window Upgrades: 16% glazing area
  • Space Heating Energy Proto: 1.0
  • Space Heating Energy: 1.0
  • Space Heating Upgrades: N/A
  • Lighting Energy: 24.0
  • Lighting Energy Proto: 10.0
  • Light Appliance: 61.0
  • Light Appliance Proto: 61.0
  • Light Eff Type: 2
  • Light EEF Per: 100.0
  • Cooling Type: Electric Air Conditioner (split system)
  • Cooling SEER: 16.0
  • Cooling Fuel: Electric
  • Cooling Energy Proto: 49.0
  • Cooling Energy: 151.0
  • Duct R Value: 8.0
  • Air Tight Upgrades: 2 SLA
  • Vent Type: Balanced supply and exhaust
  • IAQ Upgrades: 100% ASHRAE 62.2
  • Hot Water Type: Solar assisted
  • Hot Water Capacity: 120.0
  • Hot Water Efficiency: 0.800000011921
  • Hot Water Energy Proto: 2.0
  • Hot Water Energy: 26.0
  • Hot Water Fuel: Electric
  • Energy Star Rating: Meets criteria but not labeled
  • Total Energy Use: 265.0
  • Total Energy Use Proto: 124.0
  • Total Energy Savings: 52.0

Data and Resources

Additional Info

Field Value
Author Vicky Pang
Maintainer Vicky Pang
Last Updated September 16, 2016, 22:26 (Etc/UTC)
Created September 16, 2016, 22:26 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Hot - Humid
City Oahu
State HI
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 2010-07-01
Project Actual End Date 2010-07-01
Completed House Count 1
Expected House Count 1
Energy Savings Percentage 29
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1

Dataset extent

Map data © OpenStreetMap contributors
Tiles by OpenStreetMap