Reducing Air Distribution in a Four-Bedroom Produc

This test house is projected to achieve 38% source energy savings relative to the Building America House Simulation Protocols (Hendron and Engebrecht 2010) and to achieve 51% source energy savings with the installed 2.0-kW photovoltaic (PV) system. The project included improvements to the thermal enclosure and space conditioning system over the builder?s standard product, with primary changes including elimination of the standard cathedralized attic system for a vented attic assembly and relocation of the space conditioning equipment and ductwork from the attic to conditioned area of the house. The heating, ventilation, and air-conditioning (HVAC) system improvements included the use of a balanced ventilation system with enthalpy recovery instead of the builder?s standard supply-only system without enthalpy recovery, as well as the replacement of a centrally ducted space conditioning system with a multi-head MSHP system consisting of minimally ducted, lower-capacity, and higher-efficiency air handlers distributed throughout the conditioned area of the house.

DESIGN - My Design - PV

  • Description: Test house design characteristics, with installed PV system
  • House Count: 1
  • Last Update: 2013-10-11
  • Last Updated By: Ari Rapport

DESIGN - Occupied Test House with PV

  • Description: Design used for one occupied test house including PV
  • House Count: 1
  • Last Update: 2013-10-11
  • Last Updated By: Ari Rapport
  • Notes: This test house is projected to achieve 38% source energy savings relative to the Building America House Simulation Protocols (Hendron and Engebrecht 2010) and to achieve 51% source energy savings with the installed 2.0-kW photovoltaic (PV) system. The project included improvements to the thermal enclosure and space conditioning system over the builder?s standard product, with primary changes including elimination of the standard cathedralized attic system for a vented attic assembly and relocation of the space conditioning equipment and ductwork from the attic to conditioned area of the house. The heating, ventilation, and air-conditioning (HVAC) system improvements included the use of a balanced ventilation system with enthalpy recovery instead of the builder?s standard supply-only system without enthalpy recovery, as well as the replacement of a centrally ducted space conditioning system with a multi-head MSHP system consisting of minimally ducted, lower-capacity, and higher-efficiency air handlers distributed throughout the conditioned area of the house.

STRUCTURE - 7918 Platinum Court

  • Description: Occupied test house in 2013
  • Address 7918 Platinum Court San Antonio, TX
  • Last Update: 2013-10-11
  • Last Updated By: Ari Rapport

Data and Resources

Additional Info

Field Value
Author Ari Rapport
Maintainer Ari Rapport
Last Updated September 9, 2016, 22:22 (Etc/UTC)
Created April 27, 2016, 19:37 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Hot - Humid
City San Antonio
State TX
Zip Code 00000
Phase 2010 to 2015
Project Start Date 2012-01-01
Project Estimated End Date 2014-09-01
Project Actual End Date 2014-09-01
Completed House Count 2
Expected House Count 2
Energy Savings Percentage 51
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1