  • Description: Wall U value 0.035, R-49 Attic, Window U value 0.22, Floor U Value 0.029, Ventilation with balanced HRV 90% efficient, Blower door 2.0 ACH-50 (target), Heat pump 18 SEER 9.2 HSPF, Heat Pump Water Heater 2.5EF

Weather Info:

  • Location: Portland, OR
  • Elevation: 39.0
  • Fact: 0.759999990463
  • End Type: No
  • Regional Office: Seattle
  • Submitted: No
  • Approved: Yes
  • Modified: 2010-01-19
  • Stage: Design
  • Visit: No

Specification 4682

  • Percent Energy Savings: 7
  • Submitted: No
  • Approved: No
  • Floor Plan: Unknown

Specification 4683

  • Percent Energy Savings: 50
  • Submitted: No
  • Approved: No
  • Editor: Vicky Pang
  • Modified: 2010-01-19 09:30:00
  • Floor Plan: Sage Green
  • Style: Single-family detached, site built
  • House Type: Production (G3)
  • Number of Stories: 2.0
  • Number of Bedrooms: 4
  • Floor Area: 1526.0
  • Roof R Value: 45.0
  • Roof Radiant: No
  • Wall R Value: 28.5699996948
  • Wall Radiant: No
  • Wall Upgrades: U-Value: 0.035
  • Foundation Type: Slab on grade
  • Foundation R Value: 34.4799995422
  • Foundation Upgrades: U-Value: 0.029
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.219999998808
  • Space Heating Type: Air Source Heat Pump
  • Space Heating Efficiency: 9.19999980927
  • Space Heating Efficiency Type: HSPF
  • Space Heating Energy Proto: 24.0
  • Space Heating Energy: 115.0
  • Lighting Energy: 23.0
  • Lighting Energy Proto: 6.0
  • Light Appliance: 64.0
  • Light Appliance Proto: 62.0
  • Cooling Type: Air Source Heat Pump
  • Cooling SEER: 18.0
  • Cooling Energy Proto: 3.0
  • Cooling Energy: 15.0
  • Air Tight Upgrades: 2.0 ACH (50)
  • Vent Type: Balanced supply and exhaust
  • IAQ Upgrades: 90% effficient
  • Hot Water Type: Heat pump
  • Hot Water Efficiency: 2.5
  • Hot Water Energy Proto: 35.0
  • Hot Water Energy: 45.0
  • Total Energy Use: 264.0
  • Total Energy Use Proto: 131.0
  • Total Energy Savings: 50.0

Data and Resources

Additional Info

Field Value
Author Vicky Pang
Maintainer Vicky Pang
Last Updated September 16, 2016, 22:25 (Etc/UTC)
Created September 16, 2016, 22:25 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Marine
City Portland
State OR
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 2010-01-19
Project Actual End Date 2010-01-19
Completed House Count 1
Expected House Count 18
Energy Savings Percentage 28
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1