Sequoia

Weather Info:

  • Location: Las Vegas, NV
  • Elevation: 2178.0
  • Fact: 0.810000002384
  • End Type: No
  • Regional Office: Seattle
  • Submitted: No
  • Approved: Yes
  • Modified: 2004-04-16
  • Visit: No

Specification 1660

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: John Chase
  • Modified: 2003-05-21 00:00:00
  • Floor Plan: 4601
  • House Type: Unknown
  • Number of Stories: 1.0
  • Floor Area: 1379.0
  • Roof Radiant: No
  • Wall Radiant: No
  • HERS Rating: 90
  • Total Energy Savings: 15.0

Specification 1662

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: John Chase
  • Modified: 2003-05-21 00:00:00
  • Floor Plan: 4602
  • House Type: Unknown
  • Number of Stories: 2.0
  • Floor Area: 1637.0
  • Roof Radiant: No
  • Wall Radiant: No
  • HERS Rating: 90
  • Total Energy Savings: 15.0

Specification 2794

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: John Chase
  • Modified: 2004-04-15 00:00:00
  • Floor Plan: 4603
  • Number of Stories: 2.0
  • Floor Area: 2062.0
  • Roof Radiant: No
  • Wall Radiant: No
  • Foundation Insulation: 19
  • Window U Value: 0.360000014305
  • Window SHGC: 0.300000011921
  • Cooling SEER: 10.0
  • HERS Rating: 88
  • Total Energy Savings: 15.0

Specification 2795

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: John Chase
  • Modified: 2004-04-15 00:00:00
  • Floor Plan: 4603 /Bed 5
  • Number of Stories: 2.0
  • Floor Area: 2271.0
  • Roof Radiant: No
  • Wall Radiant: No
  • Foundation Insulation: 19
  • Window U Value: 0.360000014305
  • Window SHGC: 0.300000011921
  • Cooling SEER: 10.0
  • HERS Rating: 88
  • Total Energy Savings: 15.0

Specification 2796

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: John Chase
  • Modified: 2004-04-15 00:00:00
  • Floor Plan: 4604
  • Number of Stories: 2.0
  • Floor Area: 2476.0
  • Roof Radiant: No
  • Wall Radiant: No
  • Foundation Insulation: 19
  • Window U Value: 0.360000014305
  • Window SHGC: 0.300000011921
  • Cooling SEER: 10.0
  • HERS Rating: 88
  • Total Energy Savings: 15.0

Specification 2797

  • Percent Energy Savings: 15
  • Submitted: No
  • Approved: Yes
  • Editor: John Chase
  • Modified: 2004-04-15 00:00:00
  • Floor Plan: 4604 /Bed 5
  • Number of Stories: 2.0
  • Floor Area: 2656.0
  • Roof Radiant: No
  • Wall Radiant: No
  • Foundation Insulation: 19
  • Window U Value: 0.360000014305
  • Window SHGC: 0.300000011921
  • Cooling SEER: 10.0
  • HERS Rating: 88
  • Total Energy Savings: 15.0

Data and Resources

Additional Info

Field Value
Author Bob Hendron
Maintainer Bob Hendron
Last Updated September 16, 2016, 21:17 (Etc/UTC)
Created September 16, 2016, 21:17 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Hot - Dry
City Las Vegas
State NV
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 1970-01-01
Project Actual End Date 1970-01-01
Completed House Count 212
Expected House Count 1272
Energy Savings Percentage 15
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1

Dataset extent

Map data © OpenStreetMap contributors
Tiles by OpenStreetMap