SIPS

  • Description: SIPS envelope, High efficiency ductless heat pump, Heat recovery ventilation, Solar thermal domestic hot water, Advanced air leakage control, LED and CFL lighting, Beyond Code glazing

Weather Info:

  • Location: Portland, OR
  • Elevation: 39.0
  • Fact: 0.759999990463
  • End Type: No
  • Regional Office: Seattle
  • Submitted: No
  • Approved: Yes
  • Modified: 2010-01-18
  • Stage: Under Construction
  • Visit: Yes

Specification 4680

  • Percent Energy Savings: 7
  • Submitted: No
  • Approved: No
  • Floor Plan: Unknown

Specification 4681

  • Percent Energy Savings: 51
  • Submitted: No
  • Approved: Yes
  • Editor: Vicky Pang
  • Modified: 2010-01-18 00:00:00
  • Floor Plan: SIPS
  • Style: Single-family detached, site built
  • House Type: Prototype/Research House (G2)
  • Number of Stories: 2.0
  • Number of Bedrooms: 4
  • Floor Area: 2089.0
  • Roof Framing: Other
  • Roof Insulation: SIPS
  • Roof R Value: 45.0
  • Roof Radiant: No
  • Roof Upgrades: "Green Roof"
  • Wall Framing: SIP - 10 in.
  • Wall R Value: 30.0
  • Wall Radiant: No
  • Foundation Type: Slab on grade
  • Foundation R Value: 30.0
  • Foundation Upgrades: SIPS
  • Window Glazing: Double pane - low-e
  • Window Framing: Vinyl
  • Window U Value: 0.310000002384
  • Window SHGC: 0.319999992847
  • Space Heating Type: Air Source Heat Pump
  • Space Heating Efficiency: 10.0
  • Space Heating Efficiency Type: HSPF
  • Space Heating Energy Proto: 49.0
  • Space Heating Energy: 129.0
  • Space Heating Fuel: Electric
  • Space Heating Upgrades: Mini-Split Heat Pump
  • Lighting Energy: 27.0
  • Lighting Energy Proto: 7.0
  • Light Appliance: 67.0
  • Light Appliance Proto: 67.0
  • Light Eff Type: 3
  • Light EEF Per: 100.0
  • Cooling Type: Air Source Heat Pump
  • Cooling SEER: 18.0
  • Cooling Fuel: Electric
  • Cooling Energy Proto: 2.0
  • Cooling Energy: 14.0
  • Vent Type: Heat Recovery Ventilator (HRV)
  • Hot Water Type: Electric resistance
  • Hot Water Location: Interior closet
  • Hot Water Energy Proto: 12.0
  • Hot Water Energy: 46.0
  • Hot Water Fuel: Electric
  • Energy Star Rating: Meets criteria but not labeled
  • Total Energy Use: 283.0
  • Total Energy Use Proto: 138.0
  • Percent Energy Savings: 51.0
  • Total Energy Savings: 51.0

Data and Resources

Additional Info

Field Value
Author Vicky Pang
Maintainer Vicky Pang
Last Updated September 16, 2016, 22:25 (Etc/UTC)
Created September 16, 2016, 22:25 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Marine
City Portland
State OR
Zip Code 99999
Phase Before 2010
Project Start Date 1970-01-01
Project Estimated End Date 2010-11-01
Project Actual End Date 2010-11-01
Completed House Count 1
Expected House Count 1
Energy Savings Percentage 29
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1