Stapleton

  • Description: Overview:

One house under construction with a targeted energy savings of 40%

Key Partners:

Energy Efficiency Measures:

R-18 Basement insulation, exterior walls 2x6 framing with R-21 cavity insulation and R-5 insulating sheathing, vented attic with R-54 insulation, high performance windows (U=0.30; SHGC=0.30), tight building envelope ACH(50)= 1.62, HRV, 93% AFUE gas furnace, 16.7 SEER AC unit, Tankless DWH, Energy Star Appliances, 50% fluorescent lighting, 6.392 kW Sharp PV system

Other Features:

Weather Info:

  • Location: Denver, CO
  • Elevation: 5331.0
  • Fact: 0.870000004768
  • End Type: No
  • Regional Office: Denver
  • Submitted: No
  • Approved: Yes
  • Modified: 2007-05-30
  • Visit: No

Specification 2087

  • Percent Energy Savings: 7
  • Submitted: No
  • Approved: Yes
  • Modified: 2008-05-05 00:00:00
  • Floor Plan: Unknown
  • Roof Radiant: No
  • Wall Radiant: No
  • Total Energy Savings: 7.0

Data and Resources

Additional Info

Field Value
Author Brad Oberg
Maintainer Brad Oberg
Last Updated September 16, 2016, 21:20 (Etc/UTC)
Created September 16, 2016, 21:20 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Cold
City Denver
State CO
Zip Code 99999
Phase Before 2010
Project Start Date 2003-03-03
Project Estimated End Date 2003-07-28
Project Actual End Date 2003-07-28
Completed House Count 1
Expected House Count 1
Energy Savings Percentage 7
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1

Dataset extent

Map data © OpenStreetMap contributors