Vickery Village

  • Description: Overview:

30% energy savings level prototype for 70 home community.

Key Partners:

Energy Efficiency Measures:

Other Features:

* End Type: No Regional Office: Atlanta Submitted: No Approved: Yes Modified: 2006-05-01 * Visit: No

Specification 3720

  • Percent Energy Savings: 7
  • Submitted: No
  • Approved: Yes
  • Modified: 2008-05-05 00:00:00
  • Floor Plan: Unknown
  • Roof Radiant: No
  • Wall Radiant: No
  • Space Heating Capacity: 0.0
  • Total Energy Savings: 7.0

Specification 3740

  • Percent Energy Savings: 37
  • Submitted: No
  • Approved: Yes
  • Editor: Brad Oberg
  • Modified: 2006-05-17 00:00:00
  • Floor Plan: Vickery Village Hedgewood 2306
  • House Type: Unknown
  • Number of Stories: 3.0
  • Number of Bedrooms: 3
  • Floor Area: 2306.0
  • Roof Framing: Unvented attic - truss framing
  • Roof Insulation: Sprayed cellulose
  • Roof R Value: 38.0
  • Roof Radiant: No
  • Roof Upgrades: Blown-in cellulose insulation is used in the attic to achieve R-38. Unfaced R-19 fiber glass batt insulation is used in the floor of living space over the garage and floors over unconditioned spaces. Roofs have asphalt shingles.
  • Wall Framing: Wood - 2x4 - 16 in o.c.
  • Wall Insulation: Fiberglass batts
  • Wall R Value: 13.0
  • Wall Radiant: No
  • Wall Upgrades: The profile of exterior walls include: cladding material, housewrap, structural sheathing, 2x4 framing, R-13 kraft-faced fiber glass insulation batts in cavities, and drywall finish. Band joists are insulated with R-13 unfaced fiber glass insulation batts
  • Foundation Type: Conditioned basement
  • Foundation Insulation: Fiberglass batts
  • Foundation R Value: 13.0
  • Foundation Upgrades: Basement foundation walls are typically uninsulated unless the area is to be finished in which case an insulated (R-13) and drywalled wood frame wall is installed around the interior wall perimeter.
  • Window Glazing: Double pane - low-e
  • Window Framing: Wood
  • Window U Value: 0.34999999404
  • Window SHGC: 0.340000003576
  • Window Upgrades: Windows are wood-framed, double-glazed, with low-emissivity coating; U=0.35 and SHGC=0.34.
  • Space Heating Type: Air Source Heat Pump
  • Space Heating Combustion: N/A
  • Space Heating Capacity: 0.0
  • Space Heating Efficiency: 7.0
  • Space Heating Efficiency Type: HSPF
  • Space Heating Location: Basement
  • Space Heating Energy Proto: 51.0
  • Space Heating Energy: 85.0
  • Space Heating Fuel: Electric
  • Space Heating Upgrades: Electric air-source heat pump equipment has an efficiency of 6.8 HSPF and 13 SEER.
  • Lighting Energy: 24.0
  • Lighting Energy Proto: 22.0
  • Light Appliance: 26.0
  • Light Appliance Proto: 25.0
  • Cooling Type: Air Source Heat Pump
  • Cooling SEER: 13.0
  • Cooling Fuel: Electric
  • Cooling Energy Proto: 24.0
  • Cooling Energy: 62.0
  • Cooling Upgrades: Electric air-source heat pump equipment has an efficiency of 6.8 HSPF and 13 SEER.
  • Duct Type: Sheet metal / Flex
  • Duct Location: Partially in conditioned space
  • Air Distribution Location: Basement
  • Air Distribution Upgrades: To meet EarthCraft House™ guidelines total air distribution system air leakage must have a value less than 5% of the total floor area. For a 3,000 square foot house this amounts to 150 cfm of air leakage. Duct leakage to the outside is assumed to be no mo
  • Air Tight Upgrades: In order to meet EarthCraft House™ guidelines, homes require an average air-change rate resulting from natural infiltration lower than 0.35 ACH. Seal all common troublesoem air pathways (attic chase, fireplace, etc..) and seal all exterier penetrations.
  • Vent Type: Controlled supply
  • Vent Control: Other (or combination of the above)
  • Vent Capacity: 53.0
  • IAQ Upgrades: Passive supply air ventilation system and connect to the return air plenum to introduce outdoor air into the home. A mechanical damper and a controller timer regulate the outdoor air flow rate. Exhaust fans in bathrooms remove odors and moisture when switched on.
  • Hot Water Type: Electric resistance
  • Hot Water Combustion: Not Applicable
  • Hot Water Location: Basement
  • Hot Water Capacity: 50.0
  • Hot Water Efficiency: 0.879999995232
  • Hot Water Energy Proto: 26.0
  • Hot Water Energy: 37.0
  • Hot Water Upgrades: The electric water heaters typically have a 50-gallon capacity and an energy factor of approximately 0.88.
  • Benchmark Version: 12/29/04
  • Total Energy Use: 234.0
  • Total Energy Use Proto: 148.0
  • Percent Energy Savings: 37.0
  • Total Energy Savings: 37.0

Data and Resources

Additional Info

Field Value
Author Brad Oberg
Maintainer Brad Oberg
Last Updated September 16, 2016, 21:56 (Etc/UTC)
Created September 16, 2016, 21:56 (Etc/UTC)
Construction Type New Construction
Evaluation Level Test House
Climate Mixed - Humid
City Cummings
State GA
Zip Code 99999
Phase Before 2010
Project Start Date 2006-05-22
Project Estimated End Date 1970-01-01
Project Actual End Date 1970-01-01
Completed House Count 1
Expected House Count 71
Energy Savings Percentage 22
Average Estimated Annual Source Energy (MMBtu) 1
Average Conditioned Floor Area (sqft) 1