  • Homes at Easthampton Meadow

    End Type: No Regional Office: Boston Submitted: Yes Approved: No Modified: 2011-04-27 Visit: No Specification 4855 Percent Energy Savings: 0 Submitted: No Approved: No...
  • Project Home Again Phase VI

    Description: Roof: Asphalt Shingles on 30# felt on 5/8 CDX with joints taped R-23 4.5 80/20 spray foam at roof deck to create conditioned attic" Walls: Fibercement siding...
  • Test

    End Type: No Regional Office: Seattle Submitted: No Approved: No Modified: 2011-03-04 Visit: No Specification 4836 Percent Energy Savings: 0 Submitted: No Approved: No...
  • Project Home Again Phase V

    Description: Building Enclosure Roof R-30 low density open cell spray foam at roof deck to create conditioned attic Walls R-16 4" Steel SIPs Frame Floors R-13 2" high...
  • Project Home Again Phase IV

    Description: Building Enclosure Roof R-21 3.5" HDSF at roof deck to create conditioned attic Walls 2x6, 24" o.c. framing R-20 3" HDSF; stacked framing,...
  • Garrison Way

    End Type: No Submitted: No Approved: No Modified: 2011-02-04 Visit: No Specification 4835 Percent Energy Savings: 0 Submitted: No Approved: No Editor: Bob Abernethy Modified:...
  • Lake Burden

    End Type: No Submitted: No Approved: No Modified: 2011-01-20 Visit: Yes Specification 4821 Percent Energy Savings: 0 Submitted: No Approved: No Editor: Bob Abernethy...
  • Vision

    End Type: Yes Submitted: Yes Approved: No Modified: 2011-01-19 Visit: Yes Specification 4820 Percent Energy Savings: 0 Submitted: Yes Approved: No Editor: Srikanth Puttagunta...
  • Lennar-Vineyard Point

    Description: PV 0 Weather Info: Location: Sacramento, CA Elevation: 75.0 Fact: 0.75 End Type: No Regional Office: Seattle Submitted: No Approved: No Modified: 2010-08-24...
  • Net Zero Energy Research Test Facility

    Description: External Air Barrier External Board Foam Insulation Air Source Heat Pump Monocrystaline PV Array End Type: No Regional Office: Philadelphia Submitted: No Approved:...
  • Greystone

    End Type: No Regional Office: Atlanta Submitted: No Approved: No Modified: 2010-05-14 Stage: Under Construction Visit: No Specification 4790 Percent Energy Savings: 7...
  • Meadows North

    End Type: No Regional Office: Atlanta Submitted: No Approved: No Modified: 2010-05-14 Stage: Under Construction Visit: No Specification 4788 Percent Energy Savings: 7...
  • Ivy Gate at Loma Vista

    Description: R-19 walls (R-15 blown fiberglass plus R-4 foam sheathing) R-49 attic (floor) and Radiant barrer roof sheathing Windows- U .34, SHGC .26 Heating 94.7% AFUE forced...
  • Villas Model

    End Type: Yes Regional Office: Atlanta Submitted: No Approved: No Modified: 2010-04-30 Stage: Completed Visit: No Specification 4783 Percent Energy Savings: 7 Submitted: No...
  • Habitat For Humanity

    Weather Info: Location: Tampa, FL Elevation: 10.0 Fact: 0.75 End Type: Yes Regional Office: Atlanta Submitted: No Approved: No Modified: 2010-04-30 Stage: Completed Visit: No...
  • Cambria Hills

    Description: Heating & cooling: 92% AFUE furnace, 14 SEER air conditioner Tight, R-8 ducts (<5% total leakage) in unconditioned attic ASHRAE 62.2 compliant with timed...
  • Ivy Gate at Loma vista

    Description: Heating & cooling: 94.7%. Bryant furnace/19.2 SEER air conditioner Very tight ducts (< 3% total leakage) Insulated to R-8 Jump ducts and transfer grill...
  • Turtle Creek

    End Type: Yes Regional Office: Atlanta Submitted: No Approved: No Modified: 2010-04-28 Stage: Completed Visit: No Specification 4777 Percent Energy Savings: 7 Submitted: No...
  • Madison

    End Type: Yes Regional Office: Atlanta Submitted: No Approved: No Modified: 2010-04-28 Stage: Completed Visit: No Specification 4773 Percent Energy Savings: 7 Submitted: No...
  • Town of Tioga

    End Type: Yes Regional Office: Atlanta Submitted: No Approved: No Modified: 2010-04-28 Stage: Completed Visit: No Specification 4771 Percent Energy Savings: 7 Submitted: No...
  • Deep Energy Retrofit Pilot Program

    Description: super insulated enclosure, high performance heating and ventilation End Type: Yes Regional Office: Boston Submitted: No Approved: Yes Modified: 2010-04-20 Stage:...
  • Golf Cottages

    Description: Ground-source heat pump tied to de-superheater for supplemental water heating; R-20 roof deck insulation in seealed, cathedralized attic. End Type: Yes Submitted:...
  • Project Home Again Phase III

    Description: Building Enclosure Roof R-21 3.5" HDSF at roof deck to create conditioned attic Walls 2x6, 24" o.c. framing R-20 3" HDSF; stacked framing,...
  • Golf Cottages

    Description: Sealed attic with R-20 insulated roof deck; Ground Source Heat Pump (GSHP) space conditioning tied to desuperheater for DHW pre-heating; R-3 XPS insulated...
  • Cibolo Canyons

    Description: Sealed attic with insulated (R-19) roof deck; 2x6", 24" o.c. OVE framing; 17 SEER heat pump; 94% AFUE gas furnace; solar thermal water heating; 2 kW photovoltaic...
  • TESTMG

    Description: TEST End Type: No Submitted: No Approved: Yes Modified: 2010-11-22 Visit: No Specification 4755 Percent Energy Savings: 7 Submitted: No Approved: No Floor Plan:...
  • Timbercreek Eco House

    Description: Building Enclosure Ceiling R-30 spray foam at roof deck to create Conditioned attic Demilec® Walls Full OVE Framing (2x6 @ 24"o.c., single top plate, two...
  • New American Home 2011

    Description: The most noteworthy features of TNAH 2011 include the airtightness of its thermal shell and the use of solar energy for space conditioning and hot water. Under...
  • Kathryn Estates - TNAH2010

    Description: The exterior walls were constructed using a 10" thick insulated concrete form system with R-23 thermal performance with recycled polystyrene. All of the windows...
  • Markham Gardens

    End Type: Yes Regional Office: Boston Submitted: No Approved: No Modified: 2010-04-02 Stage: Completed Visit: No Specification 4742 Percent Energy Savings: 7 Submitted: No...
  • Cana House

    Description: Strawbale house, Altherma heat pump water heater for and Radiant Heating and Cooling. Weather Info: Location: Sacramento, CA Elevation: 75.0 Fact: 0.75 End Type:...
  • Willowbank Park

    End Type: No Regional Office: Seattle Submitted: No Approved: No Modified: 2010-03-29 Stage: Design Visit: No Specification 4735 Percent Energy Savings: 7 Submitted: No...
  • 36-38 Harriet St

    End Type: No Regional Office: Seattle Submitted: No Approved: No Modified: 2010-03-26 Stage: Design Visit: No Specification 4729 Percent Energy Savings: 7 Submitted: No...
  • Devens Sustainable Housing Demonstration Project

    End Type: No Regional Office: Boston Submitted: No Approved: No Modified: 2010-03-25 Stage: Planning Visit: No Specification 4726 Percent Energy Savings: 7 Submitted: No...
  • Wilcox Lane

    End Type: No Regional Office: Boston Submitted: No Approved: No Modified: 2010-03-25 Stage: Design Visit: No Specification 4725 Percent Energy Savings: 7 Submitted: No...
  • Hunting Ridge

    End Type: No Regional Office: Boston Submitted: No Approved: No Modified: 2010-03-25 Stage: Planning Visit: No Specification 4724 Percent Energy Savings: 7 Submitted: No...
  • Country Living

    End Type: Yes Regional Office: Boston Submitted: No Approved: No Modified: 2010-05-05 Stage: Completed Visit: No Specification 4723 Percent Energy Savings: 7 Submitted: No...
  • Trenton

    End Type: Yes Regional Office: Atlanta Submitted: No Approved: No Modified: 2010-03-25 Stage: Completed Visit: No Specification 4722 Percent Energy Savings: 7 Submitted: No...
  • Redding Prototype

    Description: 2-ton Freus evaporative condenser 4 zone distribution supreme quality control End Type: Yes Regional Office: Seattle Submitted: No Approved: Yes Modified:...
  • University Village on Colvin

    Weather Info: Location: Syracuse, NY Elevation: 407.0 Fact: 0.879999995232 End Type: No Regional Office: Boston Submitted: No Approved: Yes Modified: 2010-01-19 Stage:...
  • Waikulu

    Description: Metal framing: R-11 wall insulationo, R-19 attic insulation, 0.35/0.23 U-value/SHGC windows, 16 SEER HVAC unit, Ducts either buried or inside conditioned space...
  • Mololani

    Description: Metal framing: R-15 wall insulationo, R-25 attic insulation, 0.35/0.23 U-value/SHGC windows, 16 SEER HVAC unit, Ducts either buried or inside conditioned space...
  • Mololani Prototype

    Description: Metal framing: R-15 wall insulationo, R-25 attic insulation, 0.35/0.23 U-value/SHGC windows, 16 SEER HVAC unit, Ducts either buried or inside conditioned space...
  • Artistic Homes

    Description: OVE framing: R-21 wall insulationo, R-50 attic insulation,  0.31/0.31 U-value/SHGC windows,  9.0 HSPF, 15 SEER heat pump, Ducts inside conditioned space,...
  • Artistic Homes Portotypes

    Description: OVE framing: R-21 wall insulationo, R-50 attic insulation,  0.31/0.31 U-value/SHGC windows,  9.0 HSPF, 15 SEER heat pump, Ducts inside conditioned space,...
  • Sage Green

    Description: Wall U value 0.035, R-49 Attic, Window U value 0.22, Floor U Value 0.029, Ventilation with balanced HRV 90% efficient, Blower door 2.0 ACH-50 (target), Heat pump...
  • SIPS

    Description: SIPS envelope, High efficiency ductless heat pump, Heat recovery ventilation, Solar thermal domestic hot water, Advanced air leakage control, LED and CFL lighting,...
  • Snow Creek Cottages

    Description: SIP exterior walls and roof, photovoltaic system, solar hot water system, ground-coupled heat pump heating, Clearstory roof windows, heat recovery ventilation End...
  • Daybreak

    Description: Evaporative Cooler (OASys), Photovoltaic Thermal Panels (PVT), hydronic furnace and Structurally Integrated Panels (SIPs) for walls End Type: Yes Regional Office:...
  • East Fayette Street Project

    Weather Info: Location: Baltimore, MD Elevation: 154.0 Fact: 0.819999992847 End Type: No Regional Office: Philadelphia Submitted: No Approved: Yes Modified: 2010-01-17 Stage:...